| Closing Coil |
Allen Bradley |
1500 / 1502 Air |
40195-900-01 |
|
10 |
| Closing Coil |
Allen Bradley |
1152 |
62D450 |
90 V.D.C. double-coil assembly |
1 |
| Closing Coil |
Allen Bradley |
1502 Vacuum |
80153-576-51 |
120VAC |
43 |
| Closing Coil |
Allen Bradley |
1502 Vacuum |
80153-576-52 |
230VAC |
1 |
| Closing Coil |
Allen Bradley |
1502 Vacuum |
80154-134-51 |
120VAC |
0 |
| Closing Coil |
Allen Bradley |
1502 Vacuum |
JN354859-Y01 |
For 1502-V4C1D1-1 vacuum contactor
One in set of two (goes with JN354878-Y01) |
1 |
| Closing Coil |
Allen Bradley |
1502 Vacuum |
JN354878-Y08 |
For 1502-V4C1D1-1 vacuum contactor
One in set of two (goes with JN354878-Y01) |
1 |
| Closing Coil |
Allis Chalmers |
456-D |
14-183-122 |
180 V.D.C. |
1 |
| Closing Coil |
Allis Chalmers |
456-D |
14-183-122-501 |
230 V.A.C. |
0 |
| Closing Coil |
Allis Chalmers |
456-D |
14-183-180-501 |
90 V.D.C. |
11 |
| Closing Coil |
Allis Chalmers |
456-D |
14-183-181 |
125 V.D.C. |
1 |
| Closing Coil |
Allis Chalmers |
456-D |
14-183-181-501 |
125 V.D.C. |
4 |
| Closing Coil |
Allis Chalmers |
456-D |
14-183-182-501 |
250 V.D.C. |
1 |
| Closing Coil |
Cutler-Hammer |
SJA/SJS/SJD/SL |
2147A48G11 |
110-120 V.A.C. |
5 |
| Closing Coil |
Cutler-Hammer |
SL-50 |
2147A58G11 |
SL Operating Coils |
2 |
| Closing Coil |
General Electric |
IC-302 / IC-2814 |
1D300G# |
Missing or incomplete # |
14 |
| Closing Coil |
General Electric |
IC-302 / IC-2814 / IC-2812 |
1D300G102 |
110 V.A.C / 60 Cyc. |
8 |
| Closing Coil |
General Electric |
IC-302 / IC-2814 / IC-2812 |
1D300G104 |
440 V.A.C / 60 Cyc. |
2 |
| Closing Coil |
General Electric |
IC-302 / IC-2814 / IC-2812 |
1D300G124 |
230 V.A.C / 60 Cyc. |
23 |
| Closing Coil |
General Electric |
IC-302 / IC-2814 / IC-2812 |
1D300G138 |
76 V.D.C. closing coil |
6 |
| Closing Coil |
General Electric |
IC-302 / IC-2814 / IC-2812 |
1D300G144 |
175 V.D.C. closing coil |
8 |
| Closing Coil |
General Electric |
IC-302 / IC-2814 / IC-2812 |
1D300G152 |
76 V.D.C. Closing Coil |
3 |
| Closing Coil |
General Electric |
CR193 |
55D7810120G2 |
|
2 |
| Closing Coil |
General Electric |
CR193 |
55D781012G2 |
|
2 |
| Closing Coil |
ITE/Imperial |
7850 |
1501-18700 |
|
3 |
| Closing Coil |
Magnetics & Controls |
IC-302 / IC-2814 / IC-2812 |
MC144.12539 |
Factory new 175 V.D.C. / 60 Cyc. closing coil |
11 |
| Closing Coil |
MITSUBISHI |
1502 Vacuum |
JN354878-Y03 |
For 1502-V4C1D1-1 vacuum contactor
One in set of two (goes with Holding Coil JN354859-Y15) |
14 |
| Closing Coil |
MonsterControls |
IC-302 / IC-2814 / IC-2812 |
MC102.12515 |
Factory new 110 V.A.C. / 60 Cyc. closing coil
Magnetics & Controls |
10 |
| Closing Coil |
MonsterControls |
IC-302 / IC-2814 / IC-2812 |
MC124.12538 |
Factory new 230 V.A.C. / 60 Cyc. closing coil |
6 |
| Closing Coil |
MonsterControls |
7850 |
MC1501.12556 |
Factory New |
1 |
| Closing Coil |
MonsterControls |
IC-302 / IC-2814 / IC-2812 |
MC152.12540 |
Factory new 76 V.D.C. / 60 Cyc. closing coil |
1 |
| Closing Coil |
MonsterControls |
SJA/SJS/SJD/SL |
MC34G02.12477 |
110-120 V.A.C. / 60 Cyc. |
1 |
| Closing Coil |
MonsterControls |
456-D |
MC456D180.12602 |
180 V.A.C. |
6 |
| Closing Coil |
MonsterControls |
8110 Air Drawout Type A |
MC51033-632-50.12548(A) |
Equivalent to Square D 8110 Air coil #51033-632-50. 23 Ohms resistance. |
10 |
| Closing Coil |
MonsterControls |
Sq D 8110-V3540, Vacuum |
MC51034-059-50.12603(V) |
Factory new
Magnetics & Controls |
6 |
| Closing Coil |
Siemens |
88H3 |
3TY5611-0AL7 |
|
7 |
| Closing Coil |
Siemens Allis |
81H3 |
25-131-703-501 |
90 V.D.C. Closing Coil |
6 |
| Closing Coil |
Siemens Allis |
81H3 |
25-131-703-502 |
180 V.D.C. Closing Coil |
0 |
| Closing Coil |
Square D |
8110 Air Drawout Type A |
51020-056-85 |
60VDC |
4 |
| Closing Coil |
Square D |
8110 Air Drawout Type A |
51033-632-50 |
Series E |
0 |
| Closing Coil |
Square D |
8110 |
51034-306-50 |
for V3540 Vacuum Contactor |
4 |
| Closing Coil |
Square D |
8110 Air Drawout |
6130A |
Series B/C |
1 |
| Closing Coil |
Square D |
8110 Air Drawout |
L 6130 A |
Close Coil for 8110 - D 09 Series contactor |
11 |
| Closing Coil |
Toshiba |
CV452J |
5F9G0045 |
|
6 |
| Closing Coil |
Toshiba |
CV461M |
5F9G0075 |
|
6 |
| Closing Coil |
Toshiba |
DF/CV/DV/HCV |
5F9GO172 |
|
4 |
| Closing Coil |
Toshiba |
DF/CV/DV/HCV |
F-442451 |
|
4 |
| Closing Coil |
Toshiba |
DF/CV/DV/HCV |
PC18600P996 |
|
2 |
| Closing Coil |
Westinghouse |
LF |
3P-N230 |
Small coil: 220V/60Hz., 208V/60Hz., 110V/25Hz. |
1 |
| Closing Coil |
Westinghouse |
LF-50 |
441A290G01 |
For double coil unit, 40 V.D.C. |
4 |
| Closing Coil |
Westinghouse |
LF25H230 |
636C392G02 |
115 VAC |
8 |
| Closing Coil |
Westinghouse |
LF |
658C651G01 |
For 400-700 Amp contactor (LFH430-H730). 115 V.A.C., 100 V.D.C. |
5 |
| Closing Coil |
Westinghouse |
SJA/SJS/SJD/SL |
SJ7860A34G02 |
110-120 V.A.C. |
38 |